Check 16 - Head-dependent normal flux (3rd type) boundary

Checks head-dependent normal flux (3rd type) line boundary, interdomain boundary, confined and unconfined domains

This compares two single-level models that both have a confined domain that is 1000 x 1000 units in the x and y directions, specified normal flux = 0 (no-flow) boundaries at y = 500 and y =-500, and a constant head boundary h = 12.0 at x = 500.

Both models result in h=13.50 and domain discharge Qx = -T (dh/dx) = 0.01500 at x=-500. See the contour plots compared below.  Changing the model so that it is unconfined yields similar good comparisons between the model with the 3rd type boundary and the model with an equivalent finite 2nd domain (Check3rdType_unconfined.anaq and Check3rdType_unconfined_alternate.anaq).

image.png


Revision #1
Created 11 January 2024 11:03:18 by Mary Jeddere-Fisher
Updated 11 January 2024 11:05:40 by Mary Jeddere-Fisher